Difference between revisions of "Template:SQWareProduction sqwing CkpdbAllDatabases.ksh example"
m (Updated by BatchUser) |
m (Updated by BatchUser) |
||
(10 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
<pre> | <pre> | ||
− | Sourcing sqwing_Global.lib | + | Sourcing sqwing_Global.lib v2024.07 SQWareProduction for Ingres (dbSQWare) ... |
#Standard help for script sqwing_CkpdbAllDatabases.ksh: | #Standard help for script sqwing_CkpdbAllDatabases.ksh: | ||
Line 7: | Line 7: | ||
$gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -h | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -h | ||
#Display online help for this script | #Display online help for this script | ||
− | |||
− | |||
− | |||
$gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -Locale en -h | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -Locale en -h | ||
− | #Display online help for this script with forcing of the ' | + | #Display online help for this script with forcing of the 'en' locale (by default locale managed by $gvsqw_Locale) |
$gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -s | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -s | ||
#Display usage examples for this script | #Display usage examples for this script | ||
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh - | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID |
− | # | + | #Generate commands but don't execute them ! |
+ | |||
+ | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -Exec | ||
+ | #Execute sqwing_CkpdbDatabase.ksh in parallel mode for backup all databases on instance $INGRES_SID | ||
+ | |||
+ | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AGR 20 -Exec | ||
+ | #Set the waiting time in seconds between two command run, 20s here | ||
+ | |||
+ | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AGE 30 -Exec | ||
+ | #Set the waiting time in seconds between two end checks, 30s here | ||
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh - | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -ID <ListIncludeDB> -ED <ListExcludeDB> -Exec |
− | # | + | #Instead of all databases generate database list with 'in list'<ListIncludeDB> and, or 'not in list' <ListExcludeDB> |
$gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -HI <NumberOfGenerations> -Exec | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -HI <NumberOfGenerations> -Exec | ||
#Changes the number of backup generations to keep | #Changes the number of backup generations to keep | ||
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh - | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -Jnl -Exec |
− | # | + | #Backup only journals |
+ | |||
+ | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -P <NumericValue> -Exec | ||
+ | #Run sqwing_CkpdbDatabases.ksh script with a parallel degree of '<NumericValue>' | ||
+ | #Use by default the variable gvsqw_NbThreadXXX in $gvsqw_IngBin/../etc/sqwing_GlobalVar.cfg | ||
+ | #You can change this default on all your environnement if you set this variable | ||
+ | #in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg | ||
+ | |||
+ | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -OPT <Option> -Exec | ||
+ | #Add the option(s) <Option> to the command line when executing sqwing_CkpdbDatabase.ksh | ||
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh - | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AddMail 'mymail1@mydomaine.com,mymail2@mydomaine.com' -Exec |
− | # | + | #Add the mail list to the default address managed by the variable gvsqw_GlobalMail |
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -Exec | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -SendReport -Exec |
− | # | + | #Send the log by email at the end of the treatment even if there is no error |
− | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID | + | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -NoMail -Exec |
− | # | + | #Disables sending an email on error to $gvsqw_GlobalMail (by default, send on error) |
$gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec | $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec | ||
− | #Force return code to '<NumericValue>' on error (if no error, exit 0!) | + | #Force return code to '<NumericValue>' on error (if no error, "exit 0!") |
#You can also force return code of this script on all your | #You can also force return code of this script on all your | ||
#environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_CkpdbAllDatabases=<NumericValue> | #environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_CkpdbAllDatabases=<NumericValue> | ||
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg | #in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</pre> | </pre> |
Latest revision as of 15:54, 31 October 2024
Sourcing sqwing_Global.lib v2024.07 SQWareProduction for Ingres (dbSQWare) ... #Standard help for script sqwing_CkpdbAllDatabases.ksh: $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -h #Display online help for this script $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -Locale en -h #Display online help for this script with forcing of the 'en' locale (by default locale managed by $gvsqw_Locale) $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -s #Display usage examples for this script $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID #Generate commands but don't execute them ! $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -Exec #Execute sqwing_CkpdbDatabase.ksh in parallel mode for backup all databases on instance $INGRES_SID $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AGR 20 -Exec #Set the waiting time in seconds between two command run, 20s here $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AGE 30 -Exec #Set the waiting time in seconds between two end checks, 30s here $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -ID <ListIncludeDB> -ED <ListExcludeDB> -Exec #Instead of all databases generate database list with 'in list'<ListIncludeDB> and, or 'not in list' <ListExcludeDB> $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -HI <NumberOfGenerations> -Exec #Changes the number of backup generations to keep $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -Jnl -Exec #Backup only journals $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -P <NumericValue> -Exec #Run sqwing_CkpdbDatabases.ksh script with a parallel degree of '<NumericValue>' #Use by default the variable gvsqw_NbThreadXXX in $gvsqw_IngBin/../etc/sqwing_GlobalVar.cfg #You can change this default on all your environnement if you set this variable #in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -OPT <Option> -Exec #Add the option(s) <Option> to the command line when executing sqwing_CkpdbDatabase.ksh $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -AddMail 'mymail1@mydomaine.com,mymail2@mydomaine.com' -Exec #Add the mail list to the default address managed by the variable gvsqw_GlobalMail $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -SendReport -Exec #Send the log by email at the end of the treatment even if there is no error $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -NoMail -Exec #Disables sending an email on error to $gvsqw_GlobalMail (by default, send on error) $gvsqw_IngBin/sqwing_CkpdbAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec #Force return code to '<NumericValue>' on error (if no error, "exit 0!") #You can also force return code of this script on all your #environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_CkpdbAllDatabases=<NumericValue> #in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg