Template:SQWareProduction sqwing ExportFullAllDatabases.ksh example: Difference between revisions

From Wiki_dbSQWare
Jump to navigation Jump to search
m Updated by BatchUser
No edit summary
 
(47 intermediate revisions by the same user not shown)
Line 1: Line 1:
<pre>
<pre>
Sourcing sqwing_Global.lib v4.0.05 SQWareProduction for Ingres (dbSQWare) ...  
Sourcing sqwing_Global.lib v2025.07 SQWareProduction for Ingres (dbSQWare) ...  


#Standard help for script sqwing_ExportFullAllDatabases.ksh:
#Standard help for script sqwing_ExportFullAllDatabases.ksh:
Line 8: Line 8:
#Display online help for this script
#Display online help for this script


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -NoMail
gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -Locale en -h
#Desactivate sendmail on error to $gvsqw_GlobalMail (by default, send on error)
#Display online help for this script with forcing of the 'en' locale (by default locale managed by $gvsqw_Locale)


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -Exec
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -s
#Execute generated commands
#Display usage examples for this script


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID
#Generate commands but don't execute them !
#Generate commands but don't execute them !


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -Exec
#Force return code to '<NumericValue>' on error (if no error, exit 0!)
#Run sqwing_ExportFullDatabase.ksh in parallel mode for all databases on instance $INGRES_SID
#You can also force return code of this script on all your
 
#environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_ExportFullAllDatabases=<NumericValue>
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AGR 20 -Exec
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg
#Set the waiting time in seconds between two command run, 20s here
 
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AGE 30 -Exec
#Set the waiting time in seconds between two end checks, 30s here
 
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -ID <ListIncludeDB> -ED <ListExcludeDB> -Exec
#Instead of all databases generate database list with 'in list' <ListIncludeDB> and, or 'not in list' <ListExcludeDB>
 
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -HI <NumberOfGenerations> -Exec
#Changes the number of backup generations to keep


#############################
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -Consistent -Exec
#Run off sqwing_ExportFullDatabase.ksh in // mode for all databases
#Make the export with -l option
#Options to generate databases list with filters (you can mix all off them):
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -ID <listdb>
#Generate database list with 'in list':
#=> and name in ('$ListInclude')
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -ED <listdb>
#Generate database list with 'not in list':
#=> and name not in ('$ListExclude')


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -P <NumericValue> -Exec
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -P <NumericValue> -Exec
#Run sqwing_ExportFullDatabase.ksh script with a parallel degree of '<NumericValue>'
#Run sqwing_ExportFullAllDatabases.ksh script with a parallel degree of '<NumericValue>'
#Use by default the variable gvsqw_NbThreadXXX in $gvsqw_IngBin/../etc/sqwing_GlobalVar.cfg
#Use by default the variable gvsqw_NbThreadXXX in $gvsqw_IngBin/../etc/sqwing_GlobalVar.cfg
#You can change this default on all your environnement if you set this variable
#You can change this default on all your environnement if you set this variable
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID - OPT <option> -Exec
#Add the option(s) <Option> to the command
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AddMail 'mymail1@mydomaine.com,mymail2@mydomaine.com' -Exec
#Add the mail list to the default address managed by the variable gvsqw_GlobalMail
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -SendReport -Exec
#Send the log by email at the end of the treatment even if there is no error
$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -NoMail -Exec
#Disables sending an email on error to $gvsqw_GlobalMail (by default, send on error)


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec
#Force return code to '<NumericValue>' on error (if no error, "exit 0!")
#You can also force return code of this script on all your
#environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_ExportFullAllDatabases=<NumericValue>
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg
</pre>
</pre>

Latest revision as of 11:37, 6 July 2025

Sourcing sqwing_Global.lib v2025.07 SQWareProduction for Ingres (dbSQWare) ... 

#Standard help for script sqwing_ExportFullAllDatabases.ksh:


$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -h
#Display online help for this script

gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -Locale en -h
#Display online help for this script with forcing of the 'en' locale (by default locale managed by $gvsqw_Locale)

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -s
#Display usage examples for this script

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID
#Generate commands but don't execute them !

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -Exec
#Run sqwing_ExportFullDatabase.ksh in parallel mode for all databases on instance $INGRES_SID

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AGR 20 -Exec
#Set the waiting time in seconds between two command run, 20s here

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AGE 30 -Exec
#Set the waiting time in seconds between two end checks, 30s here

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -ID <ListIncludeDB> -ED <ListExcludeDB> -Exec
#Instead of all databases generate database list with 'in list' <ListIncludeDB> and, or 'not in list' <ListExcludeDB>

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -HI <NumberOfGenerations> -Exec
#Changes the number of backup generations to keep

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -Consistent -Exec
#Make the export with -l option

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -P <NumericValue> -Exec
#Run sqwing_ExportFullAllDatabases.ksh script with a parallel degree of '<NumericValue>'
#Use by default the variable gvsqw_NbThreadXXX in $gvsqw_IngBin/../etc/sqwing_GlobalVar.cfg
#You can change this default on all your environnement if you set this variable
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID - OPT <option> -Exec
#Add the option(s) <Option> to the command

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -AddMail 'mymail1@mydomaine.com,mymail2@mydomaine.com' -Exec
#Add the mail list to the default address managed by the variable gvsqw_GlobalMail

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -SendReport -Exec
#Send the log by email at the end of the treatment even if there is no error

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -NoMail -Exec
#Disables sending an email on error to $gvsqw_GlobalMail (by default, send on error)

$gvsqw_IngBin/sqwing_ExportFullAllDatabases.ksh -I $INGRES_SID -FRT <NumericValue> -Exec
#Force return code to '<NumericValue>' on error (if no error, "exit 0!")
#You can also force return code of this script on all your
#environnement if you set the variable: $gvsqw_ForcedReturnCodeScript_sqwing_ExportFullAllDatabases=<NumericValue>
#in configuration file $gvsqw_IngBin/../etc_cust/sqwing_GlobalVar.cfg